• Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications
  • Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications
  • Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications
  • Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications
  • Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications
  • Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications

Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications

Customized: Non-Customized
Certification: CCC, ISO9001, CE
Brand: Siemens
Display Type: LCD
Specification: RDG100KN
Trademark: SIEMENS
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
RDG100KN
Origin
China
HS Code
9032100000

Product Description

RDG100KN Room thermostat with KNX communications, AC 230 V, for fan coil units and universal applications

Rdg100kn Room Thermostat with Knx Communications, AC 230 V, for Fan Coil Units and Universal Applications
  1. KNX communications
  2. 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
  3. Operating modes: Comfort, Economy and Protection
  4. 2-position, 3-position or PWM control outputs
  5. Automatic or manual fan speed for 1-speed, 3-speed fan
  6. Automatic or manual heating / cooling changeover
  7. Adjustable commissioning and control parameters
  8. Minimum and maximum setpoint limitation
  9. Backlit display


Application selectable:

 
  1. 2-pipe system
  2. 2-pipe system with electrical heater
  3. 2-pipe system and radiator / floor heating
  4. 4-pipe system
  5. 4-pipe system with electrical heater
  6. 2-stage heating or cooling system
Technical Specifications
  1. Operating voltage  AC 230 V
  2. Power consumption 8 VA / 1 W
  3. Setpoint setting range 5…40 °C
  4. Switching differential Heating: 0.5…6 K Cooling: 0.5…6 K
  5. Communication  Bus: KNX (S-Mode und LTE-Mode mit Synco 700)
  6. Analog inputs, number  2
  7. Digital inputs, number  1
  8. Relay outputs Fan: 1- or 3-speed
  9. Relay outputs, number  3
  10. Relay output, switching voltage  AC 230 V
  11. Relay output, switching current  5 (4) A
  12. Triac outputs  Valve, el. heater , 2-position, PWM, 3-position
  13. Triac outputs, number  3
  14. Triac output, switching voltage  AC 230 V
  15. Triac output, switching current  Max. 1 A
  16. Type of fixing  Wall mounting with screws
  17. Degree of protection  IP30
  18. Dimensions (W x H x D)  93 x 128 x 30.8 mm